HOTLINE : 0908507021
Cảm Biến Chênh Áp FUJI Model FKC-5, EDSX6-134g
Hãng sản xuất
Warranty
Nhật bản
Mode
FKC-5, EDSX6-134g
Code
GE1-01660
Price
Call
0
Size
Range
Views
3139
Date update
19/11/2011
Quantity
Mô tả sản phẩm

Mô tả sản phẩm

 

Công Tắc Áp Suất FUJI Model FKC-5, EDSX6-134g

Model : FKC-5, EDSX6-134g
Manufacturer : FUJI ELECTRIC
Origin : JAPAN

 

 

 

 

Over range limit : To maximum static pressure limit
Output signal : 4 to 20mA DC (linear or square root) with digital signal superimposed on the 4 to 20mA signal
Power supply :

Transmitter operates on 10.5V to 45V DC at transmitter terminals.

10.5V to 32V DC for the units with op-tional arrester.

Load limitations : see figure below

 

 

 

 

 

Note: For communication with HHC(1) (Model: FXW), min. of 250 required.

Hazardous locations: (Under an application) SEE TABLE2 Zero/span adjustment:

Damping : Zero and span are adjustable from the HHC(1). Zero and span are also adjustable externally from the adjustment screw.
Adjustable from HHC or local configurator unit with LCD display.
The time constant is adjustable between 0.06 to 32 seconds.
Zero elevation/suppression:
    -100% to + 100% of URL
Normal/reverse action:
    Selectable from HHC(1)
Indication : Analog indicator or 5-digit LCD meter, as specified.
Burnout direction :

Selectable from HHC(1)
If self-diagnostic detect transmitter failure, the analog signal will be driven to either "Outphut Hold", "Output Overscale" or "Output Underscale" modes.

"Output Hold" : Output signal is hold as the value just before failure happens.
"Output Overscale" : Adjustable within the range 20.0mA to 22.5mA from HHC(1)
"Output Underscale" : Adjustable within the range 3.2mA to 4.0mA from HHC(1)
Output limits conforming to NAMUR NE43 by order.
Loop-check output:  
    Transmitter can be configured to provide constant signal 3.2mA through 22.5mA by HHC(1).
Temperature limit :  
   

Ambient: -40 to +85°C

(-20 to + 80°C for LCD indicator)

(-40 to +60°C for arrester option)

(-10 to +60°C for fluorinated oil filled transmitters)

For explosionproof units (flameproof or intrinsic safety), ambient temperature must be within the limits specified in each standard.

Process: -40 to +120°C for silicone fill sensor

-20 to +80°C for fluorinated oil fill sensor

Storage: -40 to +90°C

Humidity limit : 0 to 100% RH
Communication :

With HHC(1) (Model FXW, consult Data Sheet No. EDS8-47), following items can be remotely displayed or configured.

Note: HHC's version must be higher than 7.0 (or FXW .......1---...4), for FCX-AIII.

Local configurator with LCD display (option)
    Local configurator with 3 push button and LCD display can support following items

 

 

Programmable output linearization function:

Output signal can be characterized with "14 points linear approximation function" from HHC(1).

EMC Conformity: EN61326-1: 2006 Œ

CODE SYMBOLS

 

ACCESSORIES

Oval flanges :

(Model FFP, refer to Data Sheet No. EDS6-128)

Converts process connection to 1/2-14 NPT or to Rc1/2; in carbon steel or in 316 stainless steel.

Equalizing valves :

(Model FFN, refer to Data Sheet No. EDS6-128)

Available in Carbon steel or in 316 stainless steel and in pressure rating 16MPa or 42MPa.

Hand-held communicator : (Model FXW, refer to Data Sheet No. EDS 8-47)

 

 

ORDERING INFORMATION

When ordering this instrument, specify:
1 CODE SYMBOLS
2. Measuring range
3. Output orientation (burnout direction) when abnormality is occurred in the transmitter.
  Hold / Overscale / Underscale
  Unless otherwise specified, output hold function is suplied.
4. Output mode (linear or square root output)
  Unless otherwise specified, output mode is linear.
5. Indication method (indicated value and unit) in case of the actual scale (code D, H, P, S on 9th digit).
6. Tag No. (up to 14 alphanumerical characters), if required.
   
   
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

------------------------------------------------------------------------------------------------------------------------------------

ĐẠI LÝ PHÂN PHỐI CHÍNH THỨC TẠI VIỆT NAM CÔNG TY TNHH TM-DV-KT CAO VIỆT CƯỜNG
  Số 89 hẻm 249 Tân Kỳ Tân Quý, P.Tân Sơn Nhì, Q.Tân Phú, HCMC
Tel: 08-3813 4681/Fax: 08-3813 4680
Hotline: 0908 507 021/ 0909 951 237
| Email: sales@caovietcuong.com
Website: www.caovietcuong.com
| www.thietbidomuc.com

Other product
Anemometer - Hotwire - Model VT100

Anemometer - Hotwire - Model VT100

  • Mode
    VT100
  • Code
    3893
  • Hãng sản xuất
  • Price
    Call
Bộ Ghi Dữ Liệu - Recorder model PHU, EDS10-79b

Bộ Ghi Dữ Liệu - Recorder model PHU, EDS10-79b

  • Mode
    PHU, EDS10-79b
  • Code
    GE1-01862
  • Hãng sản xuất
  • Price
    Call
Bộ Ghi Dữ Liệu - Recorder model PHR-4, EDS10-74i

Bộ Ghi Dữ Liệu - Recorder model PHR-4, EDS10-74i

  • Mode
    PHR-4, EDS10-74i
  • Code
    GE1-01861
  • Hãng sản xuất
  • Price
    Call
Bộ Ghi Dữ Liệu - Recorder model PHL, EDS10-75i

Bộ Ghi Dữ Liệu - Recorder model PHL, EDS10-75i

  • Mode
    PHL, EDS10-75i
  • Code
    GE1-01860
  • Hãng sản xuất
  • Price
    Call
Bộ Ghi Dữ Liệu - Recorder model PHF, EDS10-77d

Bộ Ghi Dữ Liệu - Recorder model PHF, EDS10-77d

  • Mode
    PHF, EDS10-77d
  • Code
    GE1-01859
  • Hãng sản xuất
  • Price
    Call
Khe Cách Ly An Toàn Model PWX, EDS13-18b

Khe Cách Ly An Toàn Model PWX, EDS13-18b

  • Mode
    PWX, EDS13-18b
  • Code
    GE1-01858
  • Hãng sản xuất
  • Price
    Call
Diaphragm Seals 4

Diaphragm Seals 4

  • Mode
    Diaphragm Seals 4
  • Code
    GE1-01857
  • Hãng sản xuất
  • Price
    Call
Diaphragm Seals 3

Diaphragm Seals 3

  • Mode
    Diaphragm Seals 3
  • Code
    GE1-01856
  • Hãng sản xuất
  • Price
    Call
Diaphragm Seals 2

Diaphragm Seals 2

  • Mode
    Diaphragm Seals 2
  • Code
    GE1-01855
  • Hãng sản xuất
  • Price
    Call
Diaphragm Seals

Diaphragm Seals

  • Mode
    Diaphragm Seals
  • Code
    GE1-01854
  • Hãng sản xuất
  • Price
    Call